Customization: | Available |
---|---|
Light Source Direction: | Uplighting Light Source |
Maximum Measurable Area: | 3500X2500mm |
AAA standards and Higher than IEC60904-9 standard
Full spectrum: 300~1200nm, spectrum extended to 1800nmLong pulse: 15~200ms (adjustable)
Top lighting/side lighting
300-1200nm full spectrum: more truly reflects the solar module's response capability in each band
Electronic load: The scanning direction supports two modes: Isc→Voc and Voc→Isc.
Measurement objects: silicon-based thin film components, cadmium telluride, perovskite, crystalline silicon and other technical components
Item | Parameter |
Capacity |
<45s(100ms) |
---|---|
Maximum measurable area |
3500×2500mm |
Light source direction |
Uplighting light source |
Feeding method |
On-line Auto conveyor |
Solar simulator source level |
AAA |
Solar simulator standards |
IEC 60904-9 |
Calibration method |
Standard solar panel automatically calibrate light intensity in one go |
Spectral matching |
0.75-1.25 (Grade A) |
illuminance instability |
<0.5% (Grade A) |
illuminance non-uniformity |
<2% (Grade A) |
Spectral range |
10-200ms |
Flash time |
10-200ms |
Irradiance range |
200-1200W/m² |
ISC 60 times repeatability |
<0.2% |
Light source life |
≥15W times(100ms) |
Measuring range |
Voltage: 100-600V (resolution 1mV) Current: 0-10A (resolution 1mA) |
Test parameters |
Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh |
Measure power |
3000W(Max) |
Test wiring method |
Four wire system |
Software Function |
Supports code scanning gun trigger test, supports test data saving, query, and export, supports voice broadcast of test results, supports foot pedal trigger, and has automatic temperature compensation |
Temperature |
25ºC±10ºC; |
Humidity |
≤85% |
Voltage |
AC220V/50Hz/20A |
Machine size |
4630mm×4300mm×5630mm |